MCEMS-7000T

Transportable Continuous Emissions Monitoring System

  • Modular Standard Design: The MCEMS-7000T system adopts a modular design. Each module can be replaced independently, reducing downtime and enhancing the reliability and maintainability of the system.
  • Integrated Power Supply System: This system features an integrated power supply system. It only requires a single power source for operation, which reduces the complexity of power requirements and wiring, thereby enhancing portability and convenience.
  • Efficient Sample Conditioning System: This includes a handheld heated sampling probe and heated insulating pipelines. It can extract flue gas without damage and remove moisture to a 5°C dew point, ensuring the accuracy and stability of the sample.
  • Multi-component Analyzer MGA-9000: The built-in multi-component analyzer, MGA-9000, is capable of analyzing various measurements such as simultaneous measurement of NO, NO2, NOx, SO2, CO, CO2, and O2. This saves costs and simplifies operations.
  • Wireless Connection Options: Offers wireless WiFi and Bluetooth connection options. Users can achieve wireless connectivity through mobile devices, which improves work efficiency and convenience.
     

Kinetics Product

The MCEMS-7000T is an efficient, reliable, and flexible transportable continuous emissions monitoring system, designed specifically for third-party inspection companies and users for comparative testing applications. Adopting a standard modular design, integrated power system, and efficient sample conditioning system, it provides multi-component analysis and wireless connectivity options to meet the needs of various industries and applications. This system is compliant with regulatory requirements, offers cost-effectiveness, and provides data access and analysis functionalities. Our professional technical support team ensures the smooth operation of the system and addresses any issues users might encounter during their usage. We are committed to providing comprehensive solutions, aiding users in achieving accurate and dependable emissions monitoring, thus fulfilling environmental protection and regulatory requirements.

Technical Specification

Model MCEMS-7000T
Environmental Climate Conditions
Ambient Temperature 0 ~ 50 ℃ (Standard)
Relative Humidity 99% non-condensing
Sampling Conditions
Power Requirements 110 or 220VAC (50/60Hz). Maximum Consumption: MGA-9000 at 240VA, and the total for heated sampling probe, 3m heated sampling line (on platform), and sample conditioning system is up to 550VA
Cabinet Material and Color 1.5 mm thick, all-aluminum lightweight mobile case, standard RAL 7035 color scheme
Dimensions Mobile Size: 1165 x 650 x 800 mm, with load-bearing wheels
Weight Approximately 80 kg

Please refer to the following product technical specifications: